Exit and Emergency Lighting

  • Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.
Operates one or two lamps in the emergency mode for a minimum of 90-minutes.
Provides a maximum initial lumen output of 700 lumens.
Dual 120/277 voltage.
Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing.
3.6V long life, maintenance-free, rechargeable sealed NiCd battery.
Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp for minimum
90-minute emergency illumination.
Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours.
Time delay enhancement to overcome end-of-life circuit protection.
Suitable for installation inside, on top or in remote* of the fixture.
Can be used in both switched and unswitched fixtures.
UL Listed for factory or field installation.

    FLUORESCENT EMERGENCY BALLAST 700 LUMENS BAL700TD

    Product Specs Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.Operates one or two lamps in the emergency mode for a minimum of 90-minutes.Provides a maximum initial lumen output of...
  • Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.
Operates one lamp in the emergency mode for a minimum of 90-minutes.
Provides a maximum initial lumen output of 500 lumens.
Dual 120/277 voltage.
Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing.
2.4V long life, maintenance-free, rechargeable sealed NiCd battery.
Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp for minimum
90-minute emergency illumination.
Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours.
Time delay enhancement to overcome end-of-life circuit protection.
Suitable for installation inside, on top or in remote* of the fixture.
Can be used in both switched and unswitched fixtures.
UL Listed for factory or field installation.

    FLUORESCENT EMERGENCY BALLAST 500 LUMENS BAL500TD

    Product Specs Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.Operates one lamp in the emergency mode for a minimum of 90-minutes.Provides a maximum initial lumen output of 500...
  • Provides constant power output to the load during emergency mode operation.
Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.
Universal 120-277V, 50/60 Hz input.
Charge/Power "ON" LED indicator light and push-to-test switch for mandated code compliance testing.
Long-life, maintenance free, rechargeable NiCad battery.
Output short/overcurrent protection: Electronic limiting, with normal operation resuming upon removal of fault.
90 Minute minimum emergency operating time over full temperature range.
24 Hour maximum battery recharge time.
Output classification: Class 2 Compliant.
Surge protection: Per C62.41 (TVS).
Input overcurrent protection: Fusible link.
LED illuminated and remote mounted test switch.
Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in a black finish.
Provided with 2' flex conduit. Provides constant power output to the load during emergency mode operation.
Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.
Universal 120-277V, 50/60 Hz input.
Charge/Power "ON" LED indicator light and push-to-test switch for mandated code compliance testing.
Long-life, maintenance free, rechargeable NiCad battery.
Output short/overcurrent protection: Electronic limiting, with normal operation resuming upon removal of fault.
90 Minute minimum emergency operating time over full temperature range.
24 Hour maximum battery recharge time.
Output classification: Class 2 Compliant.
Surge protection: Per C62.41 (TVS).
Input overcurrent protection: Fusible link.
LED illuminated and remote mounted test switch.
Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in a black finish.
Provided with 2' flex conduit.

    CONSTANT-POWER EMERGENCY LED DRIVER BLEDEM-CP

    Product Specs Provides constant power output to the load during emergency mode operation.Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.Universal 120-277V, 50/60 Hz input.Charge/Power "ON" LED indicator light and push-to-test switch for...
  • Provides constant current (350 or 500 mA) output to the load during emergency mode operation.
Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.
Universal 120-277V, 50/60 Hz input.
Charge/Power "ON" LED indicator light and push-to-test switch for mandated code compliance testing.
Long-life, maintenance free, rechargeable NiCad battery.
Output short/overcurrent protection: Electronic limiting, with normal operation resuming upon removal of fault.
90 Minute minimum emergency operating time over full temperature range.
24 Hour maximum battery recharge time.
LED emergency driver is equipped with a switch to choose 350mA or 500mA constant current output.
Output classification: Class 2 Compliant.
Surge protection: Per C62.41 (TVS).
Input overcurrent protection: Fusible link.
LED illuminated and remote mounted test switch.
Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in a black finish. Provides constant current (350 or 500 mA) output to the load during emergency mode operation.
Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.
Universal 120-277V, 50/60 Hz input.
Charge/Power "ON" LED indicator light and push-to-test switch for mandated code compliance testing.
Long-life, maintenance free, rechargeable NiCad battery.
Output short/overcurrent protection: Electronic limiting, with normal operation resuming upon removal of fault.
90 Minute minimum emergency operating time over full temperature range.
24 Hour maximum battery recharge time.
LED emergency driver is equipped with a switch to choose 350mA or 500mA constant current output.
Output classification: Class 2 Compliant.
Surge protection: Per C62.41 (TVS).
Input overcurrent protection: Fusible link.
LED illuminated and remote mounted test switch.
Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in a black finish.

    CONSTANT-CURRENT EMERGENCY LED DRIVER BLEDEM-CC

    Product Specs Provides constant current (350 or 500 mA) output to the load during emergency mode operation.Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD.Universal 120-277V, 50/60 Hz input.Charge/Power "ON" LED indicator light and...
  • For use with lighting equipment, communications and electrical equipment, emergency lighting equipment and fire alarm & security systems.
Valve-regulated and safe to discharge in any position.
Completely sealed and maintenance free, low self-discharge.
Impact-resistant ABS housing.
Will last up to 5 years in standby applications and 200 to 1,000 cycles in cyclic applications depending on depth of
discharge.
Available in a variety of sizes and amp ratings.
Provides reliable power output in a variety of applications, resulting in greater efficiency and improved ability to recover from deep discharge.
Cycle or standby use.
Low resistance safety feature makes the batteries easy to recharge & maximizes energy output.
Standard F1 or F2 “flat lugs” type terminal.

    RECHARGEABLE SEALED LEAD ACID BATTERIES BL6/BL12

    Product Specs For use with lighting equipment, communications and electrical equipment, emergency lighting equipment and fire alarm & security systems.Valve-regulated and safe to discharge in any position.Completely sealed and maintenance free, low...
  • Kits easily convert incandescent exit signs to energy efficient LED EXIT signs..
Ultra bright, energy efficient, long lasting Red or Green LEDs provide uniform illumination. Kits easily convert incandescent exit signs to energy efficient LED EXIT signs..
Ultra bright, energy efficient, long lasting Red or Green LEDs provide uniform illumination.

    LED RETROFIT KITS RFXTE/GFXTE

    Product Specs Kits easily convert incandescent exit signs to energy efficient LED EXIT signs..Ultra bright, energy efficient, long lasting Red or Green LEDs provide uniform illumination.
  • Durable 9-gauge steel construction.
Mounting hardware provided for easy field installation.

    WIRE GUARDS WG-3

    Product Specs Durable 9-gauge steel construction.Mounting hardware provided for easy field installation.
  • Durable 9-gauge steel construction.
Mounting hardware provided for easy field installation.

    WIRE GUARDS WG-1

    Product Specs Durable 9-gauge steel construction.Mounting hardware provided for easy field installation.